Technicial Specifications
| Standby Rating | 1875/1750/1625/1500 kVA | 
| Prime Power Rating | 1700/1600/1500/1360 kVA | 
| Emissions/Fuel Strategy | Low Fuel , Low Emissions | 
| Voltage | 400 to 415 Volts | 
| Frequency | 50 Hz | 
| Speed | 1500 rpm | 
| Duty Cycle | Standby, Mission Critical, Prime, Continuous | 
| Minimum Rating | 1320 kVA | 
| Maximum Rating | 1875 kVA | 
| Engine Model | 3512B TA, V-12, 4-Stroke Water-Cooled Diesel | 
| Bore | 170 mm | 
| Stroke | 190 mm | 
| Stroke - HD | 215 mm | 
| Displacement | 51.8 l | 
| Displacement - HD | 58.56 l | 
| Compression Ratio | 14.0:1 Std 15.5:1 HD | 
| Aspiration | TA | 
| Fuel System | Electronic Unit Injection | 
| Governor Type | ADEM™ A3 | 
| Length - Minimum | 5404 mm | 
| Length - Maximum | 5515 mm | 
| Width - Minimum | 2286 mm | 
| Width - Maximum | 2286 mm | 
| Height - Minimum | 2411 mm | 
| Height - Maximum | 2411 mm | 
| Dry Weight - Genset (minimum) | 11621 kg | 
| Dry Weight - Genset (maximum) | 12034 kg | 
Advantages and Features
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
EMCP 4 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 50°C (122°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
- EU Declaration of Conformity
- EU Declaration of Incorporation
- Eurasian Conformity (EAC)
- Telecommunication Lab of China
One Safe Source
- Components used in the generator set are selected at the design stage to provide optimum package performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
World Wide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Standard Equipment
- 
                        Control System
                        
                        
                        - Warnings/shutdown indicators
 - Emergency stop pushbutton
 - 24 Volt DC operation
 - Digital indication for:
 - Lamp test
 - Emergency stop
 - Auto/start/stop control
 - Overspeed
 - Low oil pressure
 - Engine cycle crank
 - Low coolant level
 - Frequency (Hz)
 - 4 Programmable digital inputs
 - Operating hours
 - True RMS AC metering, 3-phase, +/-2% accuracy
 - Communications
 - Oil pressure
 - Speed adjust
 - DC volts
 - High coolant temperature
 - Coolant temperature
 - Amps (per phase & average)
 - Engine cool-down timer
 - RPM
 - EMCP 4.2B
 - Failure to start (overcrank)
 - Volts (L-L & L-N)
 - 4 Programmable digital outputs
 - Alarm acknowledge
 
- 
                        Governing System
                        
                        - ADEM III
 
- 
                        Cooling System
                        
                        
                        - Coolant level sensors
 - SCAC
 - Radiator fan and fan drive
 - Caterpillar extended life coolant
 - Coolant drain line with valve
 - Fan and belt guards
 
- 
                        Exhaust System
                        
                        
                        - Flanged faced outlet(s)
 - Dry exhaust manifold
 
- 
                        Fuel System
                        
                        
                        - Flexible fuel lines
 - Fuel priming pump
 - Secondary fuel filters.
 - Fuel cooler; not included with packages without radiator
 
- 
                        Generator System
                        
                        
                        - Min / max exciter
 - Caterpillar's digital voltage regulator (CDVR)
 - Class H temperature rise at 40C ambient
 - Busbar connections
 - Winding temperature detectors
 - RFI suppression
 - 3 Phase voltage sensing
 - Internal excitation (IE)
 - Random wound
 - 3 phase brushless, Salient pole
 - 6 Leads
 - NEMA Class H insulation
 
- 
                        Literature
                        
                        
                        - Parts book
 - Operation & Maintenance Manual
 
- 
                        Lube System
                        
                        
                        - Gear type lube oil pump
 - Oil filter, filler and dipstick
 - Fumes disposal
 - Oil drain lines and valve
 - Lubricating oil
 - Integral lube Oil cooler
 
- 
                        Mounting System
                        
                        - Rails - Engine/generator/radiator mounting
 
- 
                        General
                        
                        
                        - RH service
 - Flywheel and Flywheel housing-SAE
 - Caterpillar yellow with high gloss black rails & radiator
 - SAE standard rotation
 
Optional Equipment
- 
                        Air Inlet System
                        
                        
                        - Heavy duty air cleaner
 - Dual element air cleaner
 - Single element filter
 
- 
                        Exhaust
                        
                        - Exhaust mufflers
 
- 
                        Generator
                        
                        
                        - Internal excitation (IE)
 - Oversize and premium generators
 - Permanent magnet excitation (PMG)
 - Anti-condensation heater
 
- 
                        Control System
                        
                        
                        - Generator temperature monitoring
 - Neutral to ground connection
 - Local annunciator modules (Low voltage)
 - EMCP 4.3, EMCP 4.4
 - Cat connect: Ethernet telematics / Satellite telematics / Cell telematics
 - Annunciator modules (Local and remote)
 - Load share module options (LV)
 - CAN2 network equipment
 - Governors (MUI-Low voltage)
 - Customer interface options
 - Annunciator network equipment
 - Remote annunciator module (Low voltage)
 - EMCP voltage and current sensing groups
 
- 
                        Power Termination
                        
                        
                        - Circuit breakers, UL listed
 - Circuit breakers, IEC compliant
 
- 
                        Cooling System
                        
                        
                        - Installed radiators
 - Cooling system attachments
 - Water level switch gauges
 - Coolant
 
- 
                        Mounting
                        
                        
                        - Rubber anti-vibration mounts
 - IBC isolators
 - Spring type vibration isolators
 
- 
                        Starting/Charging
                        
                        
                        - Charging alternator
 - Heavy duty starting system
 - Oversize batteries
 - Air starting motor with control and silencer
 - Jacket water heater
 - Battery chargers
 
- 
                        Exhaust System
                        
                        
                        - Y Adapters
 - Mufflers
 - Flexible fittings
 - Flange and exhaust expanders
 - Elbows
 
- 
                        Factory Support
                        
                        - Factory commissioning
 
- 
                        Fuel System
                        
                        
                        - Primary fuel filter
 - Secondary fuel filters
 
- 
                        Generators and Attachments
                        
                        
                        - Low voltage generators 380, 400, 415 Volts 3 Phase, 1500 rpm
 - Space heater kit
 - 1400 and 1600 Frame
 - Pitch 0.6667
 - 6 Leads
 - Internally excitation
 - Generator conversion kits - PM to IE / IE to PM
 - Permanent magnet excitation (PMG)
 - RW
 
- 
                        General
                        
                        
                        - UL 2200 package
 - The following options are based on regional and product configuration:
 - Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
 - EU Certificate of Conformance (CE)
 
- 
                        Instrumentation
                        
                        - Pyrometer and thermocouples
 
- 
                        Lube System
                        
                        
                        - Drain GP oil pan
 - Lube oil filters
 - Oil level regulator
 - Standard sump oil pan
 - Lube oil in standard sump
 - Prelube pump groups
 
- 
                        Crankcase System
                        
                        
                        - Crankcase protection group
 - Crankcase ventilation system
 
- 
                        Mounting System
                        
                        
                        - Low efficiency isolators
 - Spring type vibration isolators
 - Low efficiency isolators puck
 - Low isolators
 
- 
                        Power Connections
                        
                        
                        - Low voltage - Package mounted circuit breakers
 - Electrically operated circuit breakers
 - Low voltage - 1400 and 1600 Frame generators
 - Low voltage - Power connection options
 
- 
                        Special Tests / Reports
                        
                        
                        - Standard generator TVA report
 - Standard engine test charge
 - Generator test report
 - PGS Test report @ 1.0 power factor
 - Custom generator TVA report
 - Generator fuel consumption test
 - PGS Test report @ 0.8 power factor
 
- 
                        Starting / Charging System
                        
                        
                        - Batteries, racks and cables
 - 10 Amp Battery charger
 - Starter cover
 - Electric starting motors
 - Jacket water heaters
 - 20 Amp Battery charger
 - Jacket water heater wiring groups
 - 35 Amp Battery charger
 
- 
                        Extended Service Coverage
                        
                        
                        - Silver - 36 ,48, 60, 120 month coverage
 - Gold - 36,48, 60, 120 month coverage
 - Cat branded commercial power system